General specifications
Model 61-362
Characteristics

Description

Display

3 ½ Digit LCD display

Display Count

3200 count, maximum reading 3199
32 segment analog bar graph

Over range Indication

“OL” displayed

Sampling Rate

2 time/second

Operating Environment:
Relative Humidity

0

°C to 50°C (32°F to 122°F) 70%RH

Temperature Coefficient

0.05X x (accuracy) per

°F (32°F to 65°F, 85°F to 122°F

Storage Environment:

-20

°C to 60°C (0°F to 140°F) at <70 relative humidity

Power source:

9V Battery (NEDA 1604)

Battery Live:

200 hours typical (alkaline)

Low Battery Indicator:

symbol indicates low battery voltage

Auto Power Off mode

Approximately 25 minutes
0.5A/250V fast acting fuse Type LA-3895

A protection Fuse

10A/600V fast acting fuse, Type LA-3897

Dimensions

5.75” H X 2.75” W X 1.5” D {without holster}

Weight:

Approximately 18.0 oz. including battery

Safety

UL1244, and Design to comply with IEC 1010-1 Cat III



RANGES and ACCURACY SPECIFICATION
61-362
Function Setting

Ranges

Accuracy

3.200V/32.00V/320.0V/ 600V

AC Voltage

50Hz to 500Hz

2.0% ± 4 digits

320.0mV/32.00V/320.0V/600V

1.2% ± 1digit

DC Voltage

3.200V

0.8% ± 1digit

320µA/3200 µA/32.00mA/320mA

2.5% ± 4 digits

10A,

AC Current

50Hz to 500Hz

3.5% ± 4 digits

320µA/3.20mA/32.00mA 2.0%

± 1 digit

DC Current

10A,

3.0% ± 1 digit

320.0

2.0% ± 3 digits

3.200k/32.00k/320.0k

1.5% ± 3 digits

3.200M

2.5% ± 3 digits

Resistance

32.00M

5.0% ± 5 digits

Continuity

beep on < 100

Not Specified

Diode Check

2V DC max

10%

± 2 digit


AC Converter:

Average responding, RMS Calibrated to Sine Wave

Overload Protection:

AC and DC Volts: 600V DC or AC rms .

Resistance, Diode, Continuity: 500V DC or AC rms
mA input: .5A/250V DC/AC rms
Amps input:
10A/600V DC/AC rms

Form number 61362

rev 1 May 2002