Before turning the switch to the “MAN”

position, ensure that the tool

connected to the appliance plug socket

is switched off.

The cleaner motor starts immediately.

b)

Switch position “Auto”

The appliance plug socket is live.

Before turning the switch to the “Auto”

position, ensure that the tool

connected to the appliance plug socket

is switched off.

The switch position and the suction hose

diameter must correspond.

The cleaner motor starts only when the tool

connected to the appliance plug socket is

switched on.

2.4

Suction force regulator (1.8)

The suction force regulator can be used to vary

the suction capacity. This permits a precise

adaptation to different substances to be picked

up.

2.5

Connecting an electric tool

Observe the maximum connected load

on the appliance plug socket (see

”Technical Data”)!

Connect the electric tool to the appliance plug

socket (1.7).

Make sure that the electric tool is switched off

when plugging it in and unplugging it.

2.6

Connecting pneumatic tools

Pneumatic tools used with the Festool IAS

system can also be operated with automatic

extraction. To achieve this, plug the coupling

connector from the exhaust-air line on the IAS

connecting piece into the coupling socket

(1.10).

The operating pressure must be above 6 bar

to ensure perfect operation, and a silencer

must be fitted to the IAS connecting piece.

Make sure that the pneumatic tool is

switched off when plugging it in and

unplugging it.

3

Changing the filter

During the following procedure, take care not

to raise dust more than is unavoidable.

Wear a P2 breathing protection mask

with health-hazardous dusts!

3.1

Changing the filter bag

- Open locking clips (1.3), remove top section

(1.1),

- Change filter bag (3.3) – see print on filter

bag,

- Dispose of the used filter bag in accordance

with statutory requirements,

- Replace top section, close locking clips.

3.2

Changing the filter element

Do not operate machine without a filter

element. This may damage the motor.

- Open locking clips (1.3), remove top section

(1.1) and set down with the filter element

facing up (Fig. 2).

- Detach filter clamping collar (2.1) with

accompanying tool and remove together

with the filter clamping washer (2.3)

- Pull a filter protection bag over the filter

element (2.2).

- Remove filter element and close the filter

protection bag with a knot.

- Dispose of the used filter element in a sealed,

dust-tight bag in accordance with statutory

requirements,

- Insert a new filter element.

- Place filter washer in position and tighten filter

clamping nut.

- Replace top section, close locking clips.

4

Application

Before commencing work, check the flow rate

monitor: Hold the suction hose closed while

the motor is running - after approx. 10 sec-

onds, an acoustic warning signal should sound.

Tools and accessories can be set down on the

storage area (1.9) ready to hand.

A hose holder can be inserted in the holes

(1.11) on the left and right of the handle and

at the back of the storage area. With the hose

holder, the suction hose can be linked up to

the tool from above. Two filter bags can be

stored in the cassette (1.5).

4.1

Vacuuming dry materials

Before using the vacuum cleaner to

evacuate dry substances, a filter bag

must always be inserted in the

container. Then the evacuated material

can be disposed of easily.

A filter bag must be used without

exception when evacuating noxious

substances!

The filter element becomes damp after

evacuating liquids. A damp filter element suffers

more wear and tear if it is used for dry

materials. Accordingly, the filter element should

be dried or replaced with a dry one before dry

operation.

4.2

Vacuuming liquids

The filter bag has to be removed before

evacuating liquids.

We recommend use of a special wet filter.

Do not evacuate combustible liquids!

If foam or liquid escapes, stop work immedi-

ately and empty the dirt container.