Eccentric sander

Technical
data

ETS 125 Q

ETS 125 EQ

Power 200

W

Speed 14,000

rpm

5,000 -

14,000 rpm

Working
strokes

28,000 rpm

10,000 -

28,000 rpm

Sanding
stroke

2.0 mm

Sanding pad

diameter 125 mm

Weight

1.1 kg (excluding cable)

Degree of
protection

/ II

The specifi ed illustrations can be found at the
beginning of the operating instructions.

Symbols

Warning of general danger

Wear ear protection!

Wear a dust mask.

Wear protective goggles.

Read the Operating Instructions/Notes!

1 Intended

use

As specifi ed, the machines are designed for sand-
ing wood, plastic, stone, composite materials,
paint/varnish, fi ller and similar materials.
Metal and materials containing asbestos must
not be processed.
The machine is particularly suitable for process-
ing smaller surfaces and overhead work because
of its size, its weight and its output.
For reasons of electrical safety the machine must
not be damp nor operated in a humid environment.
The machine may only be used for dry sanding.

The user is liable for damage and injury
resulting from incorrect usage!

2 Safety

instructions

2.1

General Safety Rules

WARNING! Read all safety warnings and
all instructions.
Failure to follow the warn-

ings and instructions may result in electric shock,
fi re and/or serious injury.

Save all warnings and instructions for future
reference.
The term „power tool“ in the warnings refers
to your mains-operated (corded) power tool or
battery-operated (cordless) power tool.

2.2 Tool-specifi c safety rules

Always wear protective goggles because

of possible dangers when sanding.

- The manufacturer’s handling and processing

instructions must be observed without fail if
explosive or self-igniting dusts are likely to oc-
cur during sanding.

- Harmful/toxic dusts can occur during your work

(e.g. lead-containing paint, some types of wood
and metal). Contact with these dusts, espe-
cially inhaling them, can represent a hazard for
operating personnel or persons in the vicinity.
Comply with the safety regulations that apply in
your country. Connect the electric power tool to
a suitable extraction system.

To protect your health, wear a P2 protec-

tive mask.

- Only for AS/NZS: The tool shall always be sup-

plied via residual current device with a rated
residual current of 30 mA or less.

2.3

Noise and vibration information

The typical values determined in accordance with
EN 60745 are:
Sound-pressure level

70 dB(A)

Sound-power level

81 dB(A)

Measuring uncertainty allowance

K = 3 dB

Wear ear protection!

Overall vibration levels (vector sum for three
directions) measured in accordance with EN
60745:
Vibration emission level
(3 directions)

a

h

= 4,5 m/s

2

Uncertainty

K = 2,0 m/s

2

The emission values specifi ed (vibration, noise)
were measured in accordance with the test con-
ditions stipulated in EN 60745 and are intended
for machine comparisons. They are also used for
making preliminary estimates regarding vibration
and noise loads during operation. The emission
values specifi ed refer to the main applications for
which the power tool is used. If the electric power
tool is used for other applications, with other tools
or is not maintained suffi ciently prior to opera-
tion, however, the vibration and noise load may be
higher when the tool is used. Take into account any

Advertising