Delta sander

Technical data

DTS 400 Q

DTS 400 EQ

Power 200

W

Speed 14,000

rpm

5,000 -

14,000 rpm

Working strokes

28,000 rpm

10,000 -

28,000 rpm

Sanding stroke

2.0 mm

Sanding pad

100 x 150 mm

(delta form)

Weight

1.1 kg (excluding cable)

Degree of
protection

/ II

The specifi ed illustrations can be found at the
beginning of the operating instructions.

Symbols

Warning of general danger

Wear ear protection!

Read the Operating Instructions/Notes!

1 Intended

use

As specifi ed, the machines are designed for sand-
ing wood, plastic, stone, composite materials,
paint/varnish, fi ller and similar materials. Metal
and materials containing asbestos must not be
processed. The machine is particularly suitable
for processing smaller surfaces and overhead
work because of its size, its weight and its output.
For reasons of electrical safety the machine must
not be damp nor operated in a humid environment.
The machine may only be used for dry sanding.

The user is liable for damage and injury
resulting from incorrect usage!

2 Safety

instructions

2.1

General Safety Rules

WARNING! Read all safety warnings and
all instructions.
Failure to follow the warn-

ings and instructions may result in electric shock,
fi re and/or serious injury.
Save all warnings and instructions for future
reference.
The term „power tool“ in the warnings refers

to your mains-operated (corded) power tool or
battery-operated (cordless) power tool.

2.2 Tool-specifi c safety rules
- Always wear protective goggles because of pos-

sible dangers when sanding.

- The manufacturer’s handling and processing

instructions must be observed without fail if
explosive or self-igniting dusts are likely to oc-
cur during sanding.

- Harmful/toxic dusts can occur during your work

(e.g. lead-containing paint, some types of wood
and metal). Contact with these dusts, espe-
cially inhaling them, can represent a hazard for
operating personnel or persons in the vicinity.
Comply with the safety regulations that apply
in your country. Connect the electric power tool
to a suitable extraction system. To protect your
health, wear a P2 protective mask.

- Only for AS/NZS: The tool shall always be sup-

plied via residual current device with a rated
residual current of 30 mA or less.

2.3

Noise and vibration information

The typical values determined in accordance with
EN 60745 are:
Sound-pressure level

70 dB(A)

Sound-power level

81 dB(A)

Measuring uncertainty allowance

K = 3 dB

Wear ear protection!

Overall vibration levels (vector sum for three di-
rections) measured in accordance with EN 60745:
Vibration emission level (3-axis)

a

h

= 4.0 m/s

2

Uncertainty

K = 2.0 m/s²

The specifi ed emissions values (vibration, noise)
– are used to compare machines.
– They are also used for making preliminary

estimates regarding vibration and noise loads
during operation.

– They represent the primary applications of the

power tool.

Increase possible for other applications, with oth-
er insertion tools or if not maintained adequately.
Take note of idling and downtimes of machine!

3

Power supply and start-up

The mains voltage must correspond to
the specifi cation on the rating plate.

Always switch the machine off before con-
necting or disconnecting the mains lead!

Advertising