8 troubleshooting – Graco AquaMax-E 3050 User Manual

Page 16

Advertising
background image

16

1)

Options / model variants

Original instructions

English

8 Troubleshooting

Fault

Cause

Remedy

Pressure drop

•

Air in the system

•

Vent the system by operating
the spray gun several times at
short intervals. If necessary,
operate the cleaner for a short
time without the high-pressure
hose connected.

•

High pressure nozzle blocked
worn

•

Clean/replace the high pres-
sure nozzle

•

Detergent tank empty

•

Top up detergent tank or set
detergent metering to “0”

Pressure fluctuations

•

Pump draws in air (only pos-
sible in suction mode)

•

Check that the suction set is
air-tight

•

Lack of water

•

Open water tap

•

Water inlet hose is too long or
its cross-section too small

•

Use specified water inlet hose

•

Lack of water caused by
blocked water filter

•

Clean the water filter in the
water connection (never work
without water filter)

•

Lack of water because max.
permissible suction height has
not been heeded

• See

instructions

The motor does not start when the
cleaner is switched on

•

The plug is not inserted prop-
erly, i.e. there is no current

•

Check the plug, lead and
switch and if necessary have
them replaced by a trained
electrician

•

The mains fuse is switched off •

Switch on the mains fuse

When the cleaner is switched on
the motor buzzes without starting

•

The mains voltage is too low or
there is a phase failure.

•

Have the electrical connection
checked

•

The pump is blocked or frozen •

Contact the GRACO customer
service

•

Incorrect cross-section or
length of the extension lead

•

Use lead with correct cross
section or length

The motor switches off

•

The overload protection has
been activated due to over-
heating or overloading of the
motor

•

Check that the mains volt-
age and the cleaner voltage
are the same. Switch off the
cleaner and allow it to cool for
at least 3 minutes

•

High-pressure nozzle is dirty

•

Change the high-pressure
nozzle

No detergents drawn in

•

Injector is dirty or suction hose
is blocked

• Clean

•

Detergent tank empty

•

Top up detergent tank

•

The cap on the FlexoPowerJet
nozzle is not set to low pres-
sure

•

See chapter 4.

Advertising