How membrane air dryer works, Pressure relief procedure, Maintenance – Graco 234418 Membrane Air Drying System User Manual

Page 5

Advertising
background image

How Membrane Air Dryer Works

309920C

5

How Membrane Air Dryer Works

Pressure Relief Procedure

The following is a basic pressure relief procedure. Be
sure to follow the specific pressure relief procedure in
your spray gun and/or fluid supply equipment manuals.

1.

Close the main air shut-off valve.

2.

Trigger the gun or dispense valve and open any
drain valves to relieve pressure.

Maintenance

Air Filter with Auto Drain 234402

To maintain maximum filtering efficiency and avoid
excessive pressure drop, the filter must be kept clean.
See Manual 309919 for cleaning and parts information.

Coalescer with Auto Drain 234397

See Manual 309919 for operation, cleaning, and parts
information.

Air Regulator 234394

Be sure air to the regulator is clean. Erratic operation or
loss of regulation is usually caused by dirt in the regula-
tor. See Manual 309924 for cleaning and parts informa-
tion.

Wet air enters
membrane module

Water vapor purges

Clean, dry air
exits module

Water vapor permeates through
hollow membrane fibers

WARNING

To avoid injury, relieve air and fluid pressure before
checking, cleaning, or repairing the equipment.

Relieve the pressure before cleaning, checking
or repairing equipment. Follow Pressure
Relief Procedure
,
above.

Check system at least once per shift to ensure
proper drainage.

It is recommended that Air Filter 234402 be
installed upstream of the coalescing filter to
remove 5 micron and larger size particles and sep-
arate large droplets of moisture from the air line.

CAUTION

Never let the liquid level in the bowl reach the base of
the coalescing element.