Operating instructions, General safety information, Machine set up – RIDGID KJ-3000 User Manual

Page 2

Advertising
background image

KJ-1590 II, KJ-2000, KJ-3000

Ridge Tool Company

1

General Safety Information

WARNING! Read these instructions
and the accompanying safety
booklet carefully before using this

equipment. If you are uncertain about any
aspect of using this tool, contact your RIDGID
distributor for more information.

Failure to understand and follow all
instructions may result in electric shock, fi re,
and/or serious personal injury.

SAVE THESE INSTRUCTIONS!

General safety

If a connection is made to a potable water system, the
system should be protected against backfl ow in accordance
with all local codes and ordinances.

Don’t spray water on the motor nor put the machine in
water.

The electric motor is splashproof (isolation class IP 55).

Jetter safety

1. Do not operate above 90

bar (KJ-1590

II)/

150 bar (KJ-2200)/205 bar (KJ-3000) or 70°C (water
temperature). Tool will do a better and safer job if
operated at recommended pressures. The KJ-1590 II
has a normal operation pressure of 80 bar (machine
can operate a couple minutes on 90 bar).

2. Use caution when handling gasoline. Refuel in

wellventilated area. Do not overfi ll fuel tank and do
not spill fuel. Make sure tank cap is closed properly.
Gasoline is extremely fl ammable and is explosive
under certain conditions.

3. Never run the engine in an enclosed or confi ned

area. Exhaust contains poisonous carbon monoxide
gas; exposure may cause loss of consciousness and
may lead to dead.

4. Be careful not to touch the muffl

er while it is hot.

To avoid severe burns or fi re hazards, let the engine
cool before transporting or storing it indoors. The

muffl

er becomes very hot during operation and

remains hot for a while after stopping the engine.

5. Never permit the end of the hose to rotate out of

the pipe being cleaned. Hose can whip causing
injury.

6. Water spray should not be pointed at any human.

High pressure spray can result in serious injury.
If fl uid seems to have penetrated skin, seek
emergency medical attention at once.

7. Jetter is designed to clean drains. Follow instructions

in Operator’s manual on machine’s uses. Other uses
may increase the risk of injury.

8. Do not spray fl ammable liquids. Spraying fl ammable

liquids could cause a fi re or explosion.

9. Do not spray toxic chemicals such as insecticide or

weed killer. Chemicals can be harmful to personnel
and machine.

10. Never clean the machine using its own spray. High

pressure spray may damage machine components.

NOTE: the normal operating pressure of the KJ-1590 II is
80 bar. You can run the machine at maximum 90 bar up to
10 minutes.

SAVE THESE INSTRUCTIONS

Machine set up

KJ-3000 assembly

Figure 1+2: Handle assembly

Figure 3: rotate hose reel backwards and set into place

over the rear guide pegs. Secure hose reel with
rear latch.

Figure 4: screw the nozzles onto the storage mounts

located on the side of the hose reel.

Figure 5: connect jetter hose

For gasoline models:

Before start-up

1. Check engine oil level. If low, add Honda 4-stroke

oil or SAE 10W-30 detergent oil. (see honda owner’s
manual enclosed for details.)

2. Check engine fuel level. If low add unleaded gasoline

with a pump octane rating of 86 or higher.

3. Remove plug in pump and replace with dipstick/

breather cap. Check the pump oil level. If oil is low,
fi ll with SAE 30 oil.

GB

KJ-1590 II, KJ-2000, KJ-3000

Operating Instructions

Advertising