Technical characteristics, Installation – Candy P 700__1 SD X AUS User Manual

Page 2

Advertising
background image

1

TECHNICAL CHARACTERISTICS

* Some models only ** Manufacturer setting

Cooking hobs 70x50

Burners

5 gas

5 gas

5 gas

5 gas

5 gas

5 gas

Reference type

P751

P751

P751

P752

P752

P752

Supply Voltage

(V/Hz)

230/50

230/50

230/50

230/50

230/50

230/50

Installed electric power

(W)

Medium burner

1

1

1

1

1

1

Large burner

2

2

2

2

2

2

Small burner

1

1

1

1

1

1

Double ring burner

1

1

Maxi burner

1

1

Fish burner

1

1

Power of gas installed:
- Natural gas 1,0 kPa (MJ/H)**

40,5

40,5

40,5

40,5

40,5

40,5

- LPG gas 2,75 kPa (MJ/H)

37,4

37,4

37,4

37,4

37,4

37,4

Electric ignition*

yes

yes

yes

yes

yes

yes

Gas safety device

yes

yes

yes

Product size

mm.

695x510

695x510

695x510

695x510

695x510

695x510

Degree protection

Class

3

3

3

3

3

3

Fig. 1

2

INSTALLATION

The Purchaser is responsible for the installation of the hob. The Manufacturer does not
accept any responsibility for any damage or loss resulting from incorrect installation,
and as such this will not covered by the Manufacturer’s Guarantee.
The hob may be installed in any worktop which is heat resistant to a temperature of
100° C, and has a thickness of 25 - 40 mm. The dimensions of the insert to be cut out
of the worktop are in shown in Fig. 1.

If the Hob is fitted next to a cabinet on either side,
the distance between the Hob and the cabinet
must be at least 150 mm (see Fig. 2); while the
distance between the hob and the rear wall must
be at least 55 mm.
If below the hob there is an accessible space,
there must be a partition panel in insulating mate-
rial (wood or similar) providing a space of at least
10 mm below the Hob (see Fig. 2).
The Hob unit is fitted by attaching the Fixing
Clamps supplied, using the holes at the base of
the unit.

VERY IMPORTANT - APPLYING THE SEALANT

Important - The diagram below shows how the sealant should be applied.

This appliance has been designed for non-professional, i.e. domestic, use.

Appropriate checks and tests have ensured that, even in the most extreme conditions,
the temperatures reached are within acceptable limits. The Hob is thermally insula-
ted (in line with Regulation EN) and may be installed: next to panels higher than
the worktop, for type «Y», or next to panels not higher than the worktop for type
«X». See technical characteristics table «Degree of protection».

Fig. 2

Partition panel

150 mm

min.

30 mm

10 mm