Candy FLGR 201 X User Manual

Page 44

Advertising
background image

Technical data

Table 2

Conversion with different gas to the regulation gas used in the factory.

Identical operations for both burners:
•
check the oven is disconnected from the electrical power supply
• open the oven door completely
• remove the bottom plate from the oven (fig. 4)
• remove the burner by unscrewing screw “A”
• remove injector “B” and replace it following the instructions shown in table 2 (check

there are no gas leaks on completing the operation)

• reinstall the oven burner
• put the plate back in place

FORNO

Ø Gas injector G30/G31 mm

0,73

Ø Gas injector G20/G31 mm

1,15

Ø Gas bypass G30/G31 mm

0,42

CAT. I3, I2, I2L sealed in factory
CAT. II2H3, II23 for gas G30/G31 screwed tight; for gas G20/G25
regulated for 0,72 kW capacity.

Rated capacity in kW

2,4

Minimum capacity in kW

0,72

Rated consumption of G30 in Kg/h

0,175

Rated consumption of G20 in m3/h

0,228

Rated consumption of G25 in m3/h

0,266

Position of ring nut G30/G31 mm

14

Air regulation (“X”) G20/G25 mm

5

Power supply voltage = 220V AC
Installed power = 1,.5kW (oven with electric grill)

Minimum air exchange needed for combustion is 4,8 m

3

/h.

Fig.4

42