Problems automatically signed – Candy LS CDE 701X NO User Manual

Page 22

Advertising
background image

The softener unit is set in the factory at level 4 (D4) as this satisfies the requirements
of the majority of users. Regulate the setting of your water softener unit according to
the degree of hardness of your water as follows: keep the delay start button pressed
in and at the same time press the stop/start button .
The factory setting "D4" will appear on the display. To change the setting, press the
start delay button . Each time you press that button the setting will increase by
one level. When you have reached "D7", the display will go back to "D1".
When the required setting appears on the display, wait for an audible signal to
confirm that the new setting has been stored in memory.

43

Regulating the water softener
with electronic programmer

The water softener can treat water with a hardness level of up to 90°fH (French
grading) or 50°dH (German grading) through 8 settings.

The settings are listed in the table below:

Level

0
1
2
3
4
5
6
7

0-5

6-10

11-20

21-30
31-40
41-50
51-60
61-90

0-3
4-6

7-11

12-16
17-22
23-27
28-33
34-50

NO

YES
YES
YES
YES
YES
YES
YES

D1
D1
D2
D3
D4
D5
D6
D7

Water

hardness

°fH

(French)

Water

hardness

°dH

(German)

Use of

regenerating

salt

Water

softener

setting

DISPLAY

ST

AR

T

Pr

1

2

I

42

Activating and deactivating the audible signal
The audible signal function can be deactivated in the following way:
keep the “Programme Selection Button”

(P)

pressed in for a few

seconds and at the same time press the stop/start button ; if the
symbol "b1" appears on the display the audible signal is activated.
Press the “Programme Selection Button”

(P)

again and the symbol

"b0" will appear which means that the audible signal has been
deactivated.
An audible signal sounds to indicate that the setting has been stored in
memory.

Pr

Pr

I

Display shows E1.

Display shows E2.

Display shows E3.

Display shows E4.

PROBLEM

CAUSE

REMEDY

The Dishwasher is able to self-assess a number of problems. The problem will
be illustrated in the display window and by an audible signal.

Water supply switched off.

Problem with electronic temperature
control.

The Water Heater Element does not
work properly or the filter mesh is
blocked.

The appliance does not discharge
water.

Switch off appliance.
Turn on water supply.
Reset the cycle.

Call Service for assistance.

Clean the Filter Mesh and if the
problem continues please contact
Service.

Check :

That the discharge hose is not

bent

Syphon is not blocked

Filters are not blocked

PROBLEMS AUTOMATICALLY SIGNED

Advertising