Vitroceramic hob without control knobs "pvs, Models pvd – Candy PVD 647 N User Manual

Page 11

Advertising
background image

SHUNT

10 GB

550x10

22 mini

VITROCERAMIC HOB WITHOUT CONTROL
KNOBS "PVS"

This connection can be made before or after the oven is

screwed into place.

Built-in oven "apertures" : Refer to
the instruction booklet concerned.

Connection to the electrical circuit, on the oven or glass ceramic
hob, should be made via the oven. For this reason, it is important
that the instructions given in the oven instructions booklet are
followed carefully.
The ceramic hob without controls "PVS", has been developed to
be used only in conjunction with specific separate control units or
built in ovens with integral hob controls.
A detailed table (supplied with ovens with integral hob control or
with independent control units) shows clearly how the hobs are
to be connected to the specified units.
Under no circumstances must the hob be connected with any
other control or oven not specified in the list.

To proceed with the connection, it is necessary to joint male
connectors

1

and

2

of the hob with the "female" connectors

3

of the oven or of the control panel.

INSTALLATION WITH OVEN

OVEN

HOB

Connection to the terminals on the terminal block

• Models PVD

The hob is fitted with a power supply cord which allows it to be
connected only to a power supply of 220-240 V between phases
or between phase and neutral.

• Connect to a socket, to choose the correct fuse, you must
refer on the table.

It is however possible to connect the hob to :

. Three phase

220-240 V3~

. Three phase

380-415 V2N~

To proceed to the new connection, you must adhere the
following instructions.

• Before making the connection, make sure that the installation
is protected by a suitable fuse, see table, and that it is fitted with
wires of a large enough section to supply the appliance normally.

• Turn over the hob, glass side against the work top, taking care

to protect the glass.

• Open the cover in the following sequence:

1

2

3

• unscrew the cable clamp "1",
• find the two tabs located on the sides,
• put the blade of a flat screw-driver in front of each tab "2" e "3",

push in and press,

• remove the cover.

To release the power supplying cord.
• remove the screws retaining the terminal block which contains

the shunt bars and the conductors of the supply cord,

• Pull out the supply cord.

• Operations to be carried out to make a new connection :
- Choose the power supply cable in accordance with the

recommendations in the table.

- Pass the power supply cable into the clamp.

- Strip the end of each conductor of

the supply cord on a 10 mm length,
by taking in account the requested
length of the cord for the connection
to the terminal block.

- According to the installation

and with the help of shunt bars which
you should have recovered in the
first operation, fix the conductor as
shown on the chart.

- Fix the cover.
- Screw the cable clamp.

Note: make sure the terminal board screws are tight.

Ph = Phase

N = Neutral

T = Earth

Monophase 220-240 V~

Two phases 220-240 V2~

Three phases 220-240 V3~

Three phases 380-415 V2N~