• Make sure that the unit is turned off.

• Remove the top cover of the unit (Note: formation of

condensation may occur after use on the inside of the

cover) and take the water tank from the unit by using

the tank handle (9).

• Turn the water tank upside down, unscrew the cap and

fill with water (9 – 10).

• Close the tank cap securely, place the tank into the unit

and put the cover back on (11).

ECON-Mode

By pressing button B, the AUTO-Mode can be changed to

ECON-Mode (symbol K) and vise versa. In the ECON-Mode,

the desired relative humidity (rH) is preset to 45%. The unit

chooses the appropriate output level Low «L» / Medium «M»

(symbol G), in order to attain the value of 45% rH as energy-

efficiently as possible.

In ECON-Mode, the rH can be changed at any time by using

button C; see C) Setting humidity level. If the output level

is changed by using button D, the ECON-Mode turns off

and the unit is operated manually; see D) Manual operation.

By pressing button B two times, the ECON-Mode can be

reactivated.

C) Setting humidity level

The appliance is fitted with a hygrostat. This measures the

relative humidity and switches the appliance off automati-

cally when the desired value is reached. The internal ven-

tilation remains turned on, to ensure an accurate reading of

the relative humidity. If the relative humidity falls below the

desired value, humidification resumes automatically. The

desired relative humidity can be adjusted in steps of 5% by

pressing button B. While selecting the desired humidity out-

put, the value display is blinking. The word DESIRED appears

on the display (symbol H). After a few seconds, the display

automatically changes to show the current value (symbol

H). Upon reaching the desired relative humidity, the display

shows DESIRED and CURRENT.

A relative humidity of between 40 and 60% is recom-

mended. The setting for the relative humidity ranges from a

minimum of 30% to a maximum of 70% relative humidity or

«CO» continuous mode.

Symbol E2

When the display shows «E2», the current relative humidity

has reached 90%. For safety reasons, the appliance swit-

ches off automatically. The appliance switches back on,

when the relative humidity falls below 85%.

A) Switch on/off

Pressing button A switches the appliance either on or off.

Button A is also used to start the decalcification mode. See

the section about «Decalcification Mode» (18 – 25). After

the unit is switched on, it is in AUTO-Mode (symbol J).

B) AUTO- / ECON-Mode

AUTO-Mode:

After the unit is switched on, it is in AUTO-Mode (symbol J).

The desired relative humidity (rH) is preset to 50%. The unit

chooses the appropriate output level Low «L» / Medium «M»

/ High «H» (symbol G), in order to attain the value of 50% rH

as quickly as possible.

In AUTO-Mode, the rH can be changed at any time by using

button C; see C) Setting humidity level. If the output level

is changed by using button D, the AUTO-Mode turns off

and the unit is operated manually; see D) Manual operation.

By pressing button B, the AUTO-Mode can be reactivated.

Operation S450

ECON

AUTO

H

M

L

L

M

H

AUTO

ECON

CURRENT

DESIRED

I

J

K