Removing / replacing a drive – Accusys ACS-7630 User Manual

Page 22

Advertising
background image

Accusys 7630

22

Removing / replacing a drive

Swapping drives

The hot swap function is available on the RAID 5 array and can be operated during run time.
RAID rebuilding will be processed automatically in the background and the ACS-7630 RAID
subsystem will record its progress. If the host system is shut down or powered off abnormally,
the ACS-7630 RAID subsystem will continue the disk rebuilding process after power is turned
on again.

A hard disk should not be replaced when the system is turned off. Doing so
may leads to loss of data. Always hot swap disks in a RAID5 array.

What if a disk fails?

If a disk drive fails, or a key switch is turned off, the red disk activity indicator of its disk carrier
will light and the alarm will sound. When this happens, you can replace the failed IDE disk with
a new one, then turn the key switch on.

The failure or removal of a single drive in a RAID5 array will not lead to
failure of the array. The failure or removal of a single drive in a RAID0 array
will lead to loss of all data on the array and the entire array must be
re-initialized.

Removing a drive from a fixed connector drive carrier

1. Unlock the appropriate disk carrier. The red

disk activity indicator will light.

2. Slide the drive carrier out of its slot.

3. Slide the disk drive to the front of the carrier

so that the IDE connector is freed from the
drive carrier.

4. Make sure the power connector is also

detached.

5. Lift out the disk drive.

Advertising