21 > pip control – Acnodes MCS User Manual
Page 27

< 2.21 > PIP Control
• Function
The computer turns the PIP function of the LCD display.
The PIP function may or not be available on a particular LCD display depending on the m odel selected
• Set PIP Control
Head er
Command
ID
Val 1
Val 2
Val 3
Val 4
Val 5
Val 6
Checksum
Foo ter
0x06, 0x4D,0x43
0x50
P IP
0x00
0x00
0x00
0x00
0x00
0x0D, 0x0 A
PIP :
The PIP function code for the LCD display
0x10
PIP OFF
0x11
Small
0x12
Large
0x13
S ide by side
•
Ack
Header
Command
ID
Val 1
Val 2
Val 3
Val 4
Val 5
Val 6
Checksum
Footer
0x4D, 0x43,0x06
0x50
PIP
0x00
0x00
0x00
0x00
0 x00
0x0D, 0 x0A
•
Nak
Header
Command
ID
Val 1
Val 2
Val 3
Val 4
Val 5
Val 6
Checksum
Footer
0x4D, 0x43,0x15
0x50
ERR
0x00
0x00
0x00
0x00
0 x00
0x0D, 0 x0A