Fes6841 – Acnodes FES 6841 User Manual
Page 34

© Copyright 2009 Acnodes, Inc.
All rights reserved. Product description and product specifications
are subject to change without notice. For latest product information,
please visit Acnodes’ web site at www.acnodes.com.
661 Brea Canyon Rd., Suite 3
Walnut, CA 91789
tel: 909.598.7388, fax: 909.598.0218, www.acnodes.com
FES6841
Fanless Embedded Controller comes with
Intel Atom N270 Processor
= 10 Power LED pin is a 1Hz toggle pulse with 50 duty cycle.
= 11 Power LED pin is a 1/4Hz toggle pulse with 50 duty cycle.
Bit 5-4: Reserved
Bit 3 : select WDTO count mode.
= 0
second
= 1
minute
Bit 2 : Enable the rising edge of keyboard Reset
(P20) to force Time-out event.
= 0 Disable
= 1 Enable
Bit 1-0: Reserved
WatchDog Timer Register II (Index=F6h, Default=00h)
Bit 7-0= 0 x 00 Time-out Disable
= 0 x 01 Time-out occurs after 1 second/minute
= 0 x 02 Time-out occurs after 2 second/minutes
= 0 x 03 Time-out occurs after 3 second/minutes
………………………………..
= 0 x FF Time-out occurs after 255 second/minutes