Always refer battery replacement and any other beacon service to a factory
authorized

Service

Center.

Find

a

Center

near

you

at

http://www.acrartex.com. Battery replacement includes servicing the beacon
by replacing all o-rings, testing the water seal and the electrical properties
and doing a full functional test on the unit.

NOTE: There are no user serviceable items inside the beacon. Do not open
the beacon except to disable (in case of faulty or accidental activation).
Otherwise, always have the beacon serviced.

WARNING: Battery contains lithium

To avoid possible fire, explosion, leakage or burn hazard, do not open,
recharge, disassemble or heat beacon above +70º C (+158º F) or
incinerate.

These products contain lithium in the battery. Various beacons may or may
not require special shipping instructions due to the lithium batteries and
changes in shipping regulations. Shipping of hazardous materials requires
special handling and documentation. MSDS sheets, along with
shipping

information,

can

be

found

on

our

website

at

http://www.acrartex.com.

In the case of the RLB-38, the product contains small batteries that are non-
hazardous. However, regulations can change. Be advised that it is best to
verify the shipping requirements at the time you are preparing to ship the
unit.

4.

Shore based maintenance for SOLAS vessels, (SBM) IMO

MSC/Circ. 1039

The Maritime Safety Committee has approved guidelines for shore-based
maintenance of satellite beacons, for the purpose of establishing
standardized procedures and minimum levels of service for the testing and
maintenance of satellite beacons. The first shore based maintenance on all
ACR EPIRBs is due at the date of the first battery replacement.

Visit ACR’s

website at

www.acrartex.com

for organizations that perform shore based

maintenance.

5.

Annual testing for SOLAS vessels, IMO MSC/Circ. 1040

SOLAS regulation IV/15.9 dictates annual testing of 406 MHz satellite
EPIRBs. Testing should be carried out using suitable test equipment
capable of performing the relevant measurements. All checks of electrical
parameters should be performed in the self-test mode, if possible. These
tests can be performed by certified ACR Battery Replacement Centers