ACR&Artex ThunderBird SSAS User Manual

Page 11

Advertising
background image

Y1-03-0180 Rev. D

8

3.4.5

Connection to beacon

Attach male TNC connector (supplied) to marine grade RG-8/U coaxial cable (Not provided) as follows:

Strip the coax cable per Figure 13.

Solder the connector pin to the center conductor.

Slide the ferrule over the cable.











CABLE CONNECTION

FIGURE 4

Slide the cable/pin assembly into the connector body. Make sure the pin goes into the center of the
connector insulator and the braid goes over the knurled part of the back of the connector.

Slide the ferrule to the back of the connector.

Using an RG-

8/U die (approx. 0.429”), crimp the ferrule tightly over the cable and connector.


Connect the male TNC cable assembly to the mating female TNC connector on antenna. For additional
protection from corrosion, spray exposed metal surfaces of connectors with Boeshield T-9 or equivalent
waterproof lubricant (not provided).










FIGURE 5

Route cable to SSAS beacon as needed, making sure to adequately secure the cable. Provide a drip loop
in the cable near the beacon to prevent water from running directly on to the beacon. Trim the cable to the
appropriate length.

Attach male SMA connector (supplied) to marine grade RG-8/U coaxial cable as follows:

Strip the coax cable (per Figure 14).

Solder the connector pin to the center conductor.

Slide the ferrule over the cable.

Slide the cable/pin assembly into the connector body. Make sure the pin goes into the center of
the connector insulator and the braid goes over the knurled part of the back of the connector.

Slide the ferrule to the back of the connector.

Using an RG-8/U die (appr

ox. 0.429”), crimp the ferrule tightly over the cable and connector.

Slide wire thru mounting
bracket to connect to
antenna

Fasten TNC cable assembly to
the mating female TNC
connector on antenna

Secure antenna to the
mounting bracket

Ferrule

Knurled Adapter end

Coaxial Cable

SSAS Connector

Advertising