ACR&Artex HydroFix HRU User Manual

Page 6

Advertising
background image

Y1-06-0276B

5

If any of the above is missing, please contact ACR Electronics’
Technical Service by email at

[email protected]

or by phone

at +1 (954) 981- 3333.

Equipment that may be required but is not included:

//

Black indelible marker

//

Phillips-head screwdriver

//

Flat-head screwdriver

//

Pliers

Notes, Cautions and Warnings

The following notes, cautions and warnings apply to all EPIRBs and
must be followed for personal safety and proper HRU replacement.

WARNING: Failure to replace the entire assembly can cause the

bracket to malfunction.

WARNING: Do not use any parts from the old HRU (the one being

replaced).

WARNING: The HRU holds down the ejector spring. Take great

care to hold the spring in place during removal and installation of the
new HRU to prevent injury.

WARNING: Stow the EPIRB in a dry location as it will activate if out

of the bracket and wet.

WARNING: Non-ACR-supplied hydrostatic release units must not be

installed in ACR Category I EPIRB brackets. ACR cannot and does not
warrant the performance of other manufacturers’ products. Installation of
a non-ACR-supplied HRU voids the warranty and potentially jeopardizes
your safety.

CAUTION: Visually check the EPIRB when removing it from the

bracket. It must be sent back to ACR for check up and/or refurbishment
if ANY of the following conditions exist:
•

Cracks to the exterior plastics

•

Activation indicator break tab is broken

•

Moisture appears inside the EPIRB

•

Lacquer is not present in one of the screws or appears to have been
tampered with


NOTE: Some parts in this kit will not be used. Refer to Figure 1 and the
instructions for your specific model for details. Discard unused parts.