ACS ACR1283L User Manual

Page 52

Advertising
background image

ACR1283L – Reference Manual

[email protected]

Version 1.00

www.acs.com.hk

Page 52 of 55


Scrolling Control Format (6 Bytes)

Where:

X Position:

Horizontal start up position. Please refer to the LCD display position below.

Y Position:

Vertical start up position. Please refer to the LCD display position below.

LCD Display Position (Total LCD Size: 128x32)

Byte 0x00h (X = 0x00h) Byte 0x01h (X = 0x01h) … Byte 0x0Fh (X = 0x0Fh)

7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 … 7 6 5 4 3 2 1 0

0x00h

0x01h

0x02h

0x03h

0x04h

0x05h

0x06h

0x07h

0x08h

0x09h

0x1Fh

Where:

Scrolling Range (Horizontal): How many 8 pixels in Horizontal after X position is scrolled
Scrolling Range (vertical):

How many pixels in Vertical after Y position is scrolled

Refresh Speed Ctrl:

Bit 0~Bit 3 – How many pixel moves pre-scrolling

Bit 4~Bit 7 – Scrolling period

Bit7

Bit6

Bit5

Bit4

Scrolling Period

0

0

0

0

1 Unit

0

0

0

1

3 Units

0

0

1

0

5 Units

0

0

1

1

7 Units

0

1

0

0

17 Units

0

1

0

1

19 Units

0

1

1

0

21 Units

Byte 0

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

X Position

Y Position

Scrolling Range

(Horizontal)

Scrolling Range

(Vertical)

Refresh Speed

Ctrl

Scrolling

Direction

Advertising