background image

ACR38x (CCID) – Reference Manual

[email protected]

Version 6.04

www.acs.com.hk

Page 16 of 58

Offset

Field

Size

Value

Description

11

bmTCCKST0

1

B0 – 0b, B7-2 – 000000b
B1 – Convention used (b1=0 for direct,

b1=1 for inverse)

Note: The CCID

ignores this bit.

12

bGuardTimeT0

1

Extra Guardtime between two

characters. Add 0 to 254 etu to the

normal guardtime of 12 etu. FFh is the

same as 00h.

13

bWaitingIntegerT0

1

WI for T=0 used to define WWT

14

bClockStop

1

ICC Clock Stop Support
00h = Stopping the Clock is not allowed
01h = Stop with Clock signal Low
02h = Stop with Clock signal High
03h = Stop with Clock either High or

Low


Protocol Data Structure for Protocol T=1 (dwLength=00000007h)

Offset

Field

Size Value

Description

10

bmFindexDindex

1

B7-4 – FI – Index into the table 7 in

ISO/IEC 7816-3:1997 selecting a clock

rate conversion factor
B3-0 – DI - Index into the table 8 in

ISO/IEC 7816-3:1997 selecting a baud

rate conversion factor

11

BmTCCKST1

1

B7-2 – 000100b
B0 – Checksum type (b0=0 for LRC,

b0=1 for CRC)
B1 – Convention used (b1=0 for direct,

b1=1 for inverse) Note: The CCID

ignores this bit.

12

BGuardTimeT1

1

Extra Guardtime (0 to 254 etu between

two characters). If value is FFh, then

guardtime is reduced by 1 etu.

13

BwaitingIntegerT1

1

B7-4 = BWI values 0-9 valid
B3-0 = CWI values 0-Fh valid