Table 2: Scooter Controller Internal Diagnostics

Flash

code

Possible Cause

Solution

1

The battery needs charging.

The battery voltage has dropped below
23.3 volts in neutral. Recharge
batteries.

2

Battery voltage is too low.

The battery has dropped past 16.5
volts and is not sufficient to allow safe
driving. Check the battery condition
and the connections.

3

Battery voltage too high

The battery has exceeded 32 volts.
Check the battery condition and the
connections.

4

Current limit time out

The motor current has reached too
high a value. Check the condition of
the motor and loom. Contact your
Service Agent.

5

Park brake fault

Check park brake conditions.

6

Speed control out of neutral

Return speed pod to neutral and rest
system. Readjust the speed lever to
neutral if necessary. Contact your
Service Agent.

7

Speed control fault

Check speed pod wiring for open or
short circuits. Check speed pot set-up.
Contact your Service Agent.

8

Motor fault

Contact your Service Agent.

9

Internal (controller) fault

Contact your Service Agent.