Actron Scan Tools PIDs Supplement User Manual

Page 6

Advertising
background image

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

4 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

PTO STATUS (OFF or ON)

Power Take Off Status

allows module to keep track of Power at Take-Off.

REL FRP (0 – 5177.27 kPa) or (0 – 750. psi)

Relative Fuel Rail Pressure

(Vacuum) is the fuel rail pressure at engine.

REL TPS (0 – 100%)

Relative Throttle Position

is the normalized relative throttle position.

SECOND AIR (AIR_STAT: UPS, DNS or OFF)

Commanded Secondary Air Status

is on newer vehicles and actuators to control pollution

control.

UPS - UP STREAM module is demanding that secondary air be added at exhaust

manifolds

DNS - DOWN STREAM module is demanding secondary air be added at catalytic

converter

OFF - Module is demanding no secondary air to be added.

ST FTRMxy (- 100 – 99.22%)

Short-term Fuel Trim Bank

calculated value represents the short-term relation of fuel meter-

ing on a fuel-injected engine.

Short-term Fuel Trim calculated value that has a positive percentage is a rich
fuel trim and if a negative percentage is present the fuel trim is lean.

ST FLTRMx (- 100 – 99.2%)

Short-term Fuel Trim

value represents the short-term relation of fuel metering on a

fuel-injected engine.

Short-term Fuel Trim value with a positive percentage is a rich fuel trim and if
a negative percentage is present the fuel trim is lean.

THR POS (0 – 100%)

Absolute Throttle Position

is the position the throttle is located. The more the throttle is

closed the less percent shown.

THROT CMD (0 – 100%)

Commanded Throttle Actuator Control

is the position of the throttle. If throttle is closed the

percent will be 0 and if wide open 100%.

TRIPS SNC CLR (0 – 255)

Number of warm-ups since diagnostic trouble codes cleared

. Warm-up is when tempera-

ture of coolant rises to at least 22ºC (40ºF) from engine starting and reaching a minimum
temperature of 70ºC (160ºF). In a diesel engine, the minimum temperature is 60ºC (140ºF.)

If there is more than 255 that the engine warms up the TRIPS SNC CLR will
remain at 255.

TROUB CODE (0000 – FFFF)

Trouble Code Parameter

will give the diagnostic trouble code that caused a freeze frame

capture. This information is helpful in diagnosing the cause of a driveability. If no freeze
frame data has been captured, this PID will be zero.

VEH SPEED (0 – 255 K/h) or (0 – 158 mph)

Vehicle Speed

shows the speed the vehicle is going.

VPWR (0 - 65.535V)

Control Module Voltage

is the power input to the control module.

Vehicles using a 42V battery may utilize multiple voltages of different systems.
Therefore, the VPWR value may be significantly different than the battery.