Placement of main unit, Placement of sensor, Troubleshooting – AcuRite 00536 Thermometer User Manual

Page 3

Advertising
background image

- 4 -

Place the main unit in a dry area free of dirt and dust. To help ensure an
accurate indoor temperature measurement, be sure to place the main
unit out of direct sunlight, and away from any heat sources or vents in
your home. There are 2 placement options for the main unit. It can be
hung on a wall using the integrated hang hole or placed on a tabletop or
other flat surface.

Placement of Main Unit

The wireless sensor MUST BE PLACED OUTDOORS to observe outdoor
temperatures. The wireless sensor must be placed less than 100 feet from
the main unit.

The wireless sensor is water resistant and is designed for general outdoor
use. However, to extend the life of the product, place the wireless sensor
in an area protected from direct weather elements. To ensure an accurate
outdoor temperature measurement, be sure the wireless sensor is placed
out of direct sunlight and away from any heat sources.

There are 2 placement options for the wireless sensor. You may hang the it
on a wall using one of the two integrated hang holes, or use string (not
included) to hang it from a suitable location like a well covered tree
branch.

Placement of Sensor

SEC TION 3 • PLACEMENT

Now that setup is complete, you must choose a location to place the wireless sensor
and the main unit. The wireless sensor MUST be placed less than 160 feet away from
the main unit.

This wireless thermometer uses radio frequency for communication, which is
susceptible to interference from other electronic devices and large metallic items or
thick walls. Always place both units at least 3 feet away from appliances ( TV,
microwave, radios, computers, etc. ) or objects that may interfere with the wireless
communication ( large metal surfaces, thick stone walls, etc. ).

TV

3

- 5 -

Troubleshooting

Problem

Bad

Wireless Sensor

Reception

Main Unit

Display Not Working

Make certain that the batteries are installed
correctly. The batteries may need replacing.

Possible Solution(s)

no bars

no temperature reading

Please DO NOT return product to the retail store.

For technical assistance and product return information, please call Customer

Care:

877-221-1252

Mon. - Fri. 8:00 A.M. to 4:45 P.M. (CST)

www.chaneyinstrument.com

• Make certain that the batteries are installed
correctly into the wireless sensor. The wireless
sensor batteries may need replacing.

• Relocate the main unit and/or the wireless
sensor. Both units must be within 160 feet
from each other.

• Make sure both units are placed at least 3 feet
from other electronic appliances and devices
that may interfere with the wireless
communication (such as TV’s, microwaves,
radios, computers etc).

• Make certain there are no large metallic
surfaces or very thick stone walls or surfaces
between the wireless sensor and the main unit.

• Metal screens or LOW-E windows may interfere
with the wireless communication.

• In some cases, relocating AND resetting the
main unit and wireless sensors (removing and
re-installing batteries) may be necessary.

NOTE: It may take up to 20 minutes for the main
unit to re-synchronize with the sensor when
batteries are replaced.

Use lithium batteries in sensor when
temperature is below -4ºF.

160 feet maximum