ACU-RITE ENC 250SS User Manual

Page 14

Advertising
background image

Acu-Rite Companies Inc.

ENC 250™

SINGLE SECTION

• Remove the thumb screw, sleeve, and washer.
• Apply silicone grease to the plug and reinstall it.

12

Apply silicone grease to plug

and reinsert it

• With the readout properly mounted, route the cable with

sufficient slack loops for machine movement to the readout.

• Secure cables by fastening with clips or ties.
• Attach the encoder connectors to the readout.

Electrical shielding ...

• Connect a ground wire from the terminal on the back of

the readout to the machine or earth ground.

• Attach a ground wire from the machine to a solid earth

ground.

• With the encoder attached to the cable connected to the

readout, check shielding by measuring resistance between
connector housing and scale unit.
Desired value: 1 ohm max.

Encoder Installation Procedure

Advertising