Acu-Rite Companies Inc.

ENC 250

™

MULTI-SECTION

Components

Each unit should consist of the following boxes:

Scale Section Boxes:
• Right End Section
• Left End Section
• Center Sections (One or more boxes depending on length)

Common Components Box:
• Scale Measuring Tape (Coiled On Spool)
• Lipseals (Coiled On Spool)
• Reading Head
• Mounting Hardware with RTV and Silicone Grease
• Reference Manual

* NOTE: Both English and metric mounting hardware have
been supplied. The mounting instructions reference to both.
Tools required depend on the fasteners being used.

2

Tools

You will need the following tools to complete the
installation:

• 0.001” Dial Indicator with Magnetic Base
• English Hex Wrench Set
• Metric Hex Wrench Set
• Dial Calipers
• Feeler Gage
• Hand Drill
• Hand Tap
• Taps (English): 1/4-20 UNC & #8-32 UNC
• Taps (Metric): M6, M4
• Drills (English): #7 (.201”), #29 (.136”), N (.302”)
• Drills (Metric): 5mm, 3.3mm, 7.7mm
• Reamer (English): .312”
• Reamer (Metric): 8mm
• Transfer Punch Set
• Hammer
• Center Punch
• Phillips Screw Driver
• Flat-tip Screw Driver
• Torque Wrench

Please follow these preparation guide lines.

• Understand your mounting requirements.
• Mount with lip seals down and away from the work area.
• Brackets should be kept as short as possible and rigid.
• Surfaces must be in good condition, clean, and free of dirt.

Remove paint from machined mounting surfaces.

• Locate the machine’s center of travel on the axis that

the encoder will be mounted to. Move the axis to the
center of travel prior to installing the encoder. Mark
a reference line on the axis so that it can easily be
returned to the center of travel.

Measuring length ...

• Machine travel can not exceed the encoder measuring

length.

• Either limit machine travel or obtain correct length scale.

“L”

• Determine the cable exit direction before installing the reading

head.

• To change the cable exit direction; remove the cover plate

and rotate the cable 180°.

Changing cable exit direction ...

Cover plate

T-10 Torx screw (2)

Plug

Armor cable hex crimp

• Encoder lip seals to face away from coolant spray.

Coolant spray ...

Mounting Preparation

“L” = Measuring length + [2.0”] 50.8mm nominal over travel

Travel is limited by stops at each end of scale

[1.0”]

25mm

[2.8”]

71.1mm