EVS Xsquare Version 2.1 User Manual User Manual
Page 29

Parameter
Value
Behavior
[1;5;0][BCF]
The application uses the first free locations on page 1, for CAM B, C
and F. Then it uses the free locations on page 5 for the CAM B, C and
F, and finally the same on page 0:
Page 1, CAM B, C and F:
110B-110C-110F- …
-199B-199C-199F
Then on page 5, CAM B, C
and F:
510B-510C-510F- …
-599B-599C-599F
Then on page 0.
010B-010C-010F- …
-099B-099C-099F
When locations CAM B, C and F on pages 1, 5 and 0 are full, it
searches first for free locations starting on page after page 0 (page 2,
since 1 is full in this case) with CAM filter B,C and F.
123A
The application uses the 123A location only. If the LSMID is not free,
the job will return the following error 'Clip already exists on
XT'
.
123[ACE]
The application uses the first free location starting from clip number
123, with a filter on CAM A, C and E only:
123A-123C-123E
124A-125C-125E …
999A-999B-999C
010A-010C-010E …
099A-099C-099E …
122A-122C-122E
123? or
123[ABCDEF]
The application uses the first free location starting from clip number
123, checking all cameras of a clip before trying next clip number:
123A-123B-…-123F
124A-124B-…-124F …
999A-999B-…-999F
010A-010B-…-010F …
099A-099B-…-099F