Spi spo, One sensor, multiple parameters, Did you know – GE Healthcare SPiO2 Faith in Pleth User Manual

Page 2

Advertising
background image

SPI

SPI

SpO

2

S

P

i

O

2

Nociception
Antinociception Balance

SP

I

(Surgical Pleth Index) refl ects the

patient’s hemodynamic responses
to both opioid delivery and surgical
stimuli during general anesthesia

2-6, 8

.

Clinical Evidence

Combined Hypnosis & SP

I

monitoring

has shown to reduce Remifentanil
consumption by

22.7% to 25%.

7, 9

Combined Hypnosis & SP

I

monitoring

has proven to reduce the incidence
of unwanted perioperative events
by

85%.

7

GE SpO

2

has history of innovation

for more than 20 years through the
legacy of Datex-Ohmeda, and provides
Advanced Plethysmographic
Technologies.

Accuracy, Reliability,
and Performance, even in
challenging situations.

One of the highest performances for
SpO

2

and Pulse Rate

13

.

The accuracy of GE Healthcare TruSignal
SpO

2

technology exceeds the ISO 9919

standards of four digits, proven in 3
studies

12

.

One Sensor,

Multiple Parameters

During general
anesthesia
, the use of
excessive or insuffi cient
analgesic medication
may lead to peri- and
post-operative adverse
events

1

.

Assessing a patient’s

oxygenation level is

one of the key elements

in helping clinicians

develop the best course

of treatment for their

patients

10, 11

.

100

65

70

75

80

85

90

95

Average Reference CO-Oximeter

IL682 & OSM3 (Functional SaO2)

CARESCAPE V100 monit

or

65

70

75

80

85

90

95

100

14

12

10

8

6

4

2

0

Chen 2010

Bergmann 2012

4,8

12,3

9,5

3,6

Remifentanil g/kg/hr

-22,7%

(p<0.05)

-25%

(p<0.006)

Control
S

P

i

DRUG TITRATION

ACCURACY

0,00

1,00

2,00

3,00

4,00

5,00

GE TruSignal occuracy

During Ultra-low to Low Perfusion

GE TruSignal occuracy

During Ultra-low to Impaired Perfusion

GE TruSignal occuracy

During Ultra-low to Normal Perfusion

GE TruSignal occuracy

During Motion Artifact Condition

GE TruSignal occuracy

During Stationary Conditions

GE TruSignal occuracy

In Normal Conditions

2,70

2,50

1,90

1,90

1,70

1,40

A

rms

A

rms

requirement by

pulse oximetry standard

RELIABILITY

PERFORMANCE

300

250

200

150

100

50

0

Control

S

P

i

-85%

(p<0.01)

Number of Events

Hypertension

Hypotension

Bradycardia

Movement

QUALITY OF CARE

SP

I

index is part of the

Adequacy of Anesthesia (AoA)

concept which may help clinicians to assess patient’s
responses to anesthetic agents, opioids and NMBAs
during general anesthesia.

Surgical Pleth Index has shown :
• Signifi cant correlation with surgical stress level

2, 6, 8

.

• Signifi cant correlation with remifentanil amount

4, 6

.

• Better sensitivity to surgical stimuli than HR, BP, or RE

5

.

• Better correlation to opioid amount thanHR, PPGA, RE, or SE

3

.

• No sensitivity to the variation of hypnotic drug amount

3

.

• GE algorithms apply specifi c calibration curves based
on each sensor’s optical characteristics.
• Each GE TruSignal sensor is individually tested and
calibrated.
• GE

SpO

2

Systems are compliant with the Medical Devices

Directive (CE Mark Directive 93/42, Article 12).

AoA BalView

SpO

2

Did You Know?