Differential pressure and t, Time – M&C TechGroup SP3000 Data sheet User Manual
Page 3
Advertising
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
[email protected] • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
2.9
Technical specifications and illustrations are without
obligation, subject to modifications. 10.04/11.12
∆P and T90 at flow of:
100
200
500
1000
1500
Nl/hr
∆P with new filter element F-3SS150
0,006
0,012
0,040
0,110
0,215
bar
∆P with new filter element S-2K150
0,003
0,005
0,02
0,058
0,135
bar
T90-time for SP3000 without tube
6
3,5
1
<0,5
<0,5
s
Dimensions
SP3000 basic version with option back purging type RS and heating type HEX4
Dimensions in mm
Differential pressure and T
90
-time
540
200
133
360
440
270
407
340
140
40
207
RS
HEX4
Advertising