Gas cooler serie EC

®

ECP 1000

ECP 2000

ECP 3000

Part number with glass heat exchanger

01 K 1000

01 K 2100

01 K 3100

Part number with stainl. steel heat exchanger

01 K 2000

01 K 2200

01 K 3210

Part number with PVDF heat exchanger

01 K 3000

01 K 2300

01 K 3300

Number of heat exchanger

1

2

1

Gas flow rate per heat exchange

max. 150 Nl/h**

max. 350 Nl/h**

Ambient temperature

+5 to +45 °C, +50 °C*

+5 to +50 °C

+5 to +50 °C

Storage temperature

-20 to +60°C

Sample outlet dew point

range of adjustment: +2 °C ..... +15 °C, factory setting: +5 °C

Dew point stability

± 0,1 °C at constant conditions

Sample inlet temperature

max. 180 °C**

Sample inlet dew point

max. 80 °C**

Total cooling power at +25 °C ambient

54 KJ/h

97,2 KJ/h

97,2 KJ/h

Power consumption

100 VA

110 VA

110 VA

Main connection

230 V ± 10%, 50Hz or 115 V ± 10%, 60Hz

Ready for working

< 10 min.

Electrical connection

Terminals 2,5 mm

2

, cable gland 2 x PG 11.

Status alarm: 2 changeover contacts

Contact rating: 250V, 2A, 500VA, 50W, Alarm point: ∆ T ±3 °C zu T

soll

Case protection

IP 22; EN 60529

Electrical standard

EN 61010

Case colour

RAL 9005

Method of mounting

wallmounting

Dimension/Weight

5,5 kg

7 kg

7 kg

Heatƒexchanger
Material of heat exchanger

Duranglass

®

PVDF

stainless steel 316Ti

Admissible gas pressure

3

2)

/ 2

3)

3 / 2

3)

10 bar

Sample gas connection

for tube ø6 mm, 8 o. 10 mm*

G 1/4’’ i

G 1/4’’ i, NPT*

Condensate connection

for tube ø12 mm, 10 o. 8 mm*

G 3/8’’ i

G 3/8’’ i, NPT*

∆ P per heat exchanger at

1 mbar at 150 l/h

1 mbar at 150 l/h

5 mbar at 350 l/h

Stagnant space per heat exchanger

50 ml

50 ml

100 ml