MECHANICAL INSTALLATION
For the mounting dimensions, see illustration 7.
Mount the pumps in such a way that the ventilator can suck sufficient cooling air.
Make sure that nobody can touch the ventilator. Mount the pumps at the highest point in the
system and/or mount them with the pump head downwards in order to avoid the collection of
condensate inside the pump head. This measure increases the service life.
Illustration 2 Dimensions (mm) MP47-Z-BPR150
11.2
ELECTRICAL CONNECTION
When executing electrical mounting works, please respect the appropriate safety instructions. Before
connecting the pump, take care that the electrical connection is voltage-free.
The diaphragm pumps MP47-Z-BPR150 must not be used in ha-
zardous locations.
W A R N I N G !
Wrong supply voltage can destroy the equipment.
When connecting the pump, please ensure that the supply voltage
is identical with the information provided on the type plate! A
deviation of max. +6 % or -10 % from the indication on the type
plate is allowed.