Charging

Cycle Applications: Limit initial current to 20.0A. Charge until battery voltage

(under charge) reaches 14.4 to 14.7 volts at 68°F (20°C). Hold at 14.4 to 14.7

volts until current drops to under 750mA. Battery is fully charged under these

conditions, and charger should be disconnected or switched to “float” voltage.

“Float” or “Stand-By” Service: Hold battery across constant voltage source of

13.5 to 13.8 volts continuously. When held at this voltage, the battery will seek its

own current level and maintain itself in a fully charged condition.

Note: Due to the self-discharge characteristics of this type of battery, it is

imperative that they be charged within 6 months of storage, otherwise permanent

loss of capacity might occur as a result of sulfation.

Chargers

Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH.

Please refer to the Charger Selection Guide in our specification sheets for “C-Series

Switch Mode Chargers” and “Transformer Type A and F Series”. Please contact our

Technical department for advice if you have difficulty in locating suitable models.

®

Further Information

Please refer to our website www.power-sonic.com for a complete range of useful

downloads, such as product catalogs, material safety data sheets (MSDS), ISO

certification, etc..

Constant Current & Power Discharge Ratings

MODEL

FINAL

VOLTAGE

AMPS/WATTS PER CELL @ 25° C

5 MIN

10 MIN

15 MIN

20 MIN

30 MIN

45 MIN

60 MIN

A

W

A

W

A

W

A

W

A

W

A

W

A

W

PG-12V75 FR

1.80

145

458

124

326

108

262

95

212

78

160

56

121

45

98

1.75

166

470

135

335

118

268

105

218

83

165

61

125

46

100

1.67

190

514

155

357 135.5

274

114

230

87.5

172

60.5

129

45

104

1.60

235

528

174

366

140

285

115

236

86.3

178

60

132

44.5

106

C

ap

ac

ity

R

et

en

tion

R

at

io

(%

)

Standing Period (Months)

100

80

60

40

0

0 2 4 6 8 10 12 14 16 18 20

40

o

C

(104

o

F)

30

o

C

(86

o

F)

20

o

C

(68

o

F)

5

o

C

(41

o

F)

Charging is not

necessary unless

100% of capacity

is required.

Charging before

use is necessary

to help recover

full capacity.

Chargemayfail

to restore full

capacity. Do not

let batteries reach

this state.

Discharge Characteristics

Discharge Time vs. Discharge Current

Shelf Life & Storage

Discharge Current (A)

Discharge T

ime

Discharge Time

Terminal V

oltage (V)

10

9

8
7
6
5

4

3

60

50

40
30
20
10

8

6
4

1 2 4

6

7

9 12

20 30 50 75 150

0

(min

)

(h

)

225 375

2

40°C (104°F)
25°C ( 77°F)

0°C ( 32°F)

75A 45A

19.5A 12.9A

7.5A

150A

225A

4.0A

3

5 10

20

30

60 2 3

5

10 20

(min)

(h)

13

12

11

10.8

9.6

9

7.6

0

10

10.5

Ambient Temperature: 25°C(77°F)

PG-12V75 

FR

 12 Volt  80 AH 

@ 20-hr. rate

, 75 AH

 @ 10-hr. rate

CORPORATE OFFICE • 7550 Panasonic Way • San Diego, CA 92154 • USA • Tel: +1-619-661-2020 • Fax: +1-619-661-3650

CUSTOMER SERVICE

Tel: +1-619-661-2030

Fax: +1-619-661-3648

[email protected]

INTERNATIONAL SALES

Tel: +1-650-364-5001

Fax: +1-650-366-3662

[email protected]

DOMESTIC SALES

Tel: +1-619-661-2020

Fax: +1-619-661-3650

[email protected]

TECHNICAL SUPPORT

Tel: +1-619-661-2020

Fax: +1-619-661-3648

[email protected]

Contact Information

www.power-sonic.com

0111 1M

© 2011. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners.

Advertising