Check the open circuit voltage of the battery to see if it has any shorted cells - there should be about
2.15 V/cell for a properly charged battery (divide the battery voltage by two to get the number of
cells). If the battery voltage looks correct then you may be trying to charge a battery which has too
large a capacity for the charger (see charging notes and tips).

RATTLE - If you think you hear a rattle inside the charger it is probably only a loose terminal strip
screw. Once the output cable is attached the rattle should go away.

MAINTENANCE INSTRUCTIONS

CLEANING - Unplug the charger before attempting any cleaning. If it becomes necessary to clean the
enclosure, wipe the exterior of the enclosure with a damp cloth and a mild detergent. Do not use an
abrasive cleanser. Do not spray cleaners directly onto the charger or immerse unit in water.

BATTERY CHARGER SPECIFICATIONS

Operating temperature:

32 to 104°F (0° to 40°C )

Storage temperature:

-40° to 176° F (-40° to 80°C )

Dimensions:

H 3.8" (9.65 cm) x W 2.8" (7.1 cm) x D 2.8" (7.1 cm)

Weight:

Less than 1.5 Ibs (0.68 kg) with standard output cable

Power Requirements:

120 V-, 60 Hz, .2 A RMS


OUTPUT RATINGS: @ 25°C

PSC-6300A
Charge Amps (lmax) 300 mA ± 2%
Charge Voltage

6.86 ± 0.06

Switch Amps (lsw)

40 mA ± 5%

Max. Continuous
Load w/ Battery

150 mA


PSC-61000A
Charge Amps (lmax) 1000 mA ± 2%
Charge Voltage

6.84 ± 0.06

Switch Amps (lsw)

75 mA ± 5%

Max. Continuous
Load w/ Battery

500 mA


PSC- 12300A
Charge Amps (lmax) 300 mA ± 2%
Charge Voltage

13.68 ± 0.12

Switch Amps (lsw)

40 mA ± 5%

Max. Continuous
Load w/ Battery

150 mA

Advertising