Construction








VR1 : LM317

VR2 : LM337

9. Voltage regulators

VR...








When you want to use the maximal 20W dissipation

mount the optional heat sink, ordernr. : HS4003.

Apply a little heat conducting paste (obtain from your

specialized dealer) to one side of an insulation plate and
press it with this side against the heatsink, there were the
component has to be fitted.

Then apply a little heat conducting paste to the component

itself, fit the component onto the heatsink and fix it by means
of an insulation tube, an 15mm M3 bolt and a nut.

10. Heatsink

15mm M3 bolt

insulation plate

M3 nut

insulation tube

1

heat conducting paste