Velleman VMB6PBN User Manual

Page 11

Advertising
background image

VMB6PBN – ed.1 |Push-button interface

11

Switching programs:

At certain points in time a pushbutton can be locked/unlocked or an action can be simulated. Up to 85 program steps
are possible.

A program step consists of following parts:

Channel
The concerned pushbutton (1...8) for which the program step is intended.

Program selection
Defines to which program a step belongs.
Following options are available:

• Summer

program

• Winter

program

• Holiday

program


Point in time
The time (day and hour) at which the program step is carried out.

• Day

setting:

o

A certain day of the week (Monday, Tuesday... Sunday)

o

All working days (Monday through Friday)

o

Every weekend (Saturday and Sunday)

o

All days except Sunday

o

All days of the week

o

On date: a certain date (1...31) of a certain month (January ... December)

o

Every month on a certain day (1...31) of every month

• Hour

setting:

o

At a certain hour (hour and minutes)

o

At wake-up time 1 (plus or minus a number of quarters)

o

At wake-up time 2 (plus or minus a number of quarters)

o

At bed-time 1 (plus or minus a number of quarters)

o

At bed-time 2 (plus or minus a number of quarters)

o

At sunrise (plus or minus a number of quarters)

o

At sunset (plus or minus a number of quarters)

Action
Following actions can be realized:

• Simulate a push on a pushbutton

• Simulate a long push on a pushbutton

• Simulate releasing a pushbutton

• Simulate pulse-control for which time-out can be set between:

o

0.25

sec

o

1 sec and 2 min, in steps of 1 sec

o

2 min and 5 min, in steps of 15 sec

o

5 min and 30 min, in steps of 30 sec

o

30 min and 1 hour, in steps of 1 min

o

1 hour and 5 hours, in steps of 15 min

o

5 hours and 10 hours, in steps of 30 min

o

10 hours and 18 hours, in steps of 1 hour

• Locking or unlocking a pushbutton

Activating/deactivating the switching program:

For each pushbutton the switching program can be activated or deactivated. This can be done via the VelbusLink
program or via pushbuttons that are connected to the Velbus.
Following functions can be realized:

• The switching program of a pushbutton is not executed as long as another Velbus pushbutton is closed.

• The switching program of a pushbutton is not executed as long as another Velbus pushbutton is open.

• The switching program of a pushbutton is not executed during a certain time-out period by a push on another

Velbus pushbutton. Choose to reactivate or deactivate the switching program next time the other pushbutton is
operated again.