Velleman projects K2579 Assembly instructions User Manual

Page 9

Advertising
background image

9

Hook-up and use




Connect the unit with a 12VDC regulated power supply as shown in the example.



Turn the trimmer all the way counterclockwise.



Push the START button. The relay will be activated momentarily.



The position of the trimmer determines the ON-time. Turn it clockwise to increase the ON-time.



Increase the value of C2 for an even longer activation duration.



The unit can be stopped at any time by pressing the STOP button.



The START and STOP buttons can be mounted in a remote location. Make sure to use screened cable,
avoid outside interference and keep the distance between the switches and the PCB as short as possible.



The timer is equipped with a relay output that is galvanically separated from the rest of the circuit for extra
safety. The connection example lists the function of the pins of the relay contacts.



If the relay is used to switch important inductive loads, such as electric motors or transformers, it may be
necessary to install a snubber network across the relay contacts to avoid excessive contact wear.





Ensure that the power supply of the circuit is sufficiently HF decoupled. Noise impulses entring
trough the power supply may start and stop the circuit unnecessarily.

13. Hook-up and use

H2579IP'2_rev1.pub
page 9

Monday, February 11, 2013 13:19