Velleman VM148 User Manual

Page 5

Advertising
background image

5

Introduction:
Thank you for choosing Velleman. This multifunctional digital thermostat module allows you to control and monitor the room
temperature.

Modules needed:
Apart from the VM148 module, you will be needing a 12VDC power supply. Use an external contactor with currents higher than 3A.

Possibilities:

The module allows you to maintain the room temperature between 2 programmed limits. Example: The room temperature must
not drop below 20°C. Once the heating is activated, the room temperature must reach 22°C before being deactivated.

Control of the air conditioning system.

Temperature monitoring in e.g. a housing or greenhouse, of a liquid...).

General definitions:

Hysteresis: Temperature difference between temp° A and temp °B (min. 0.5°C). Temp°A will automatically rise with 0.5°C if
the two temperature settings have been programmed identically.

Heating mode: Activation of the heating when the measured temperature ≤ programmed

temperature B until the measured temperature > programmed temperature A. Heating mode is
activated when temp°A > temp°B.

Cooling mode: Activation of the air conditioning system when the measured temperature >
programmed temperature B until the ambient temperature drops below programmed tempera-

ture A. Cooling mode is activated when temp°A < temp°B.
A red dot is displayed in the right corner below when the relay, and consequently the

connected device, is activated.

Temperature display: The actual temperature and the settings can be displayed in ° Celsius

and ° Fahrenheit.

Heating

Temp. A > B

Off

on

Temp. A

Temp. B

Cooling

Temp. A< B

on

off

Temp. B

Temp. A