Velleman VMB1BL User Manual

Page 9

Advertising
background image

Velbus manual VMB1BL – edition 1 – rev.2.0

9

L

H

UP

DWN

BUS

+

12V

-

COM

L

DOWN UP

TIME

ADDR

TERM

VELBUS

Direct push button control
(up and down)

12V supply

Up operation mode LED

Manuel up operation

Down operation mode LED

Up indication LED

Direct push button control
(COM connection)

Relay contacts for blind motor control

Forwarding LED

Reception LED

Power LED

Address setting

Switch-off setting

Termination

Down indication LED

Manuel down operation

OUT

PB

USE:


Remove the lid on the blind control module using a small screwdriver to modify the configuration.


Replace the lid.

Termination:

If the module is connected at the start or end of a cable on the VELBUS, place the ‘TERM’ jumper.

Remove the jumper in all other cases.

If different cable wiring topologies (tree, star, loop, ...) are used, place a jumper on the end module of the longest
cable only, NOT on each end point.