16

VMB4RYNO 4-channel relay module user manual - version 1

40

Cancel inhibit at pushbutton
press

Pressing the pushbutton will transfer the internal status to the
relay.

A light sensor will switch on the garden lighting at dusk. A
pushbutton on the control panel will inhibit the output at 23h00; a
second pushbutton will cancel this inhibition at 06h00 via the
weekly program. This will keep the garden lighting switched off
between 23h00 and 06h00.

Some functions allow you to set the switch-off time, the switch-on delay or the pulse and pause time between:

o

1 sec and 2 min in steps of 1 sec

o

2 min and 5 min in steps of 15 sec

o

5 min and 30 min in steps of 30 sec

o

30 min and 1 hour in steps of 1 min

o

1 hour and 5 hours in steps of 15 min

o

5 hours and 10 hours in steps of 30 min

o

10 hours and 24 hours in steps of 1 hour

o

2

days

o

3

days

o

no switch-off timer