Velleman VM147 User Manual

Cut-out template

Advertising
background image

Power supply :

9 - 12VDC / 50mA

+

-

4

3

2

1

1

2

3

down up

D : Protection diode (1N4148)
R
: Relay coil (max. 100mA)

Enter

Up

Down

Menu : Set preset,

pulse time, options

Equal out indicator

"Set preset"

indicator

"Set pulse out

time" indicator

"Set options"

indicator

Run Mode :



Impuls at input : IN-'UP'

(count up)

or IN-'Down'

(count down).



Change actual counter UP/DOWN with Up-Down keys
Hold for High Speed Scrolling.



Press ENTER for counter reset "0000" or load the preset value (L Pr)

Press "MENU"

PRESS

Set preset value with UP / DOWN

Save option with "ENTER"

Puls lenght when equal OUT is triggered



0 = as long as equal



1 = approx. 100ms



2 = approx. 200ms


Save option with "ENTER"

PULSE

RST

Reset when preset value is reached?

RST.y : Yes
RST.n : No

Save option with "ENTER"

dbc

Debounce inputs

dbc.y : Yes

input frequence = 10Hz max.


dbc.n : No

input frequence = 400Hz max.


Save option with "ENTER"

1

GND

2

IN "down"

3

IN "up"

4

Equal OUT

VM147 : panel counter module

Cut-out

template

55mm

38,5m

m

Rv

D

+12V

OUT (4)

GND (1)

R

1K

Example