Test Load
Note: It is advisable to conduct this test as a routine check to ensure that you are obtaining
reliable data.
Note: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at their own expense.
Changes and modifications not expressly approved by Veris Technologies could void the user’s
authority to operate the Veris 3100.
Implement
Prior to operating the implement for the first time, it is important to check the following:
1) All fasteners – some may have loosened during shipment.
2) Coulter electrode isolation – check so see that no metal part of the any coulter electrode
is in contact with the implement frame. This may be by visual inspection or by connecting
one lead of an ohmmeter to the individual coulter electrode, and the other to a grounded
fastener on the frame. If the coulter electrode is properly isolated, no reading will be
obtained. Make sure that all electrode coulter clamp bolts are properly tightened to
prevent lateral movement of the coulter electrode