V-Tech DT-DCU Manual User Manual

Dcu - user manual, Terminal descriptions 2. specifications

Advertising
background image

Page 1/8

1 2 3 4 5 6

ON

1 2 3 4

ON

DCU

LED 2
LED 1

PD

DIP-6
DIP-4

PC

BUS/IN

BUS/OUT

BUS/DS

+12(camera1)

GND(camera1)

VG(camera1)

V1(camera1)

+12(camera2)

GND(camera2)

VG(camera2)

V2(camera2)

COM

NC/NO

EB+

EB-

●

●

COM:

●Contact●relay●Common●terminal

●

●

NC/NO:

Contact●relay●Normally-Closed●/●Normally-

Opened●terminal

●

●

EB+, EB-:

Contact●activate●button

●

●

DIP-6:

Main●DIP●switches

●

●

DIP-4:

Switches●for●Lock/Light●control

●

●

PC:

Repeated●Code●Checking,●if●there●are●repeated●

Code●setting●on●all●the●DCUs●and●Doorstations,●the●

LED1●and●LED●2●will●flashing●for●10●seconds

●

●

PD:

Video●test●button,●press●this●button,●the●

Doorstation●will●call●the●Monitor●with●User●Code●01,●

and●output●the●Video●from●Camera1.

●

●

BUS/IN, BUS/OUT:

Connect●to●the●Bus●Line

●

●

BUS/DS:

●Connect●to●Door●Station

●

●

LED1:

Lock/Light●indicator

●

●

LED2:

Power/Video●signal●indicator

●

●

+12:

Power+●for●CCTV●camera

●

●

GND:

Power-●for●CCTV●camera

●

●

VG:

Video●Ground●for●CCTV●camera

●

●

V1, V2:

Video●Core●for●CCTV●camera

DCU - User Manual

The●DCU●unit●is●a●Multi●function●device●designed●for●DT●system●to●connect●2●CCVT●cameras●and●control●light●or●
lock(one●light●and●one●lock●can●be●supported●in●the●system,●and●they●must●be●connected●to●two●separate●DUCs).●Note●
that●this●unit●can●only●be●used●in●the●DT●intercom●system.●

●

● Supply●power●to●the●Camera●directly.

●

● Two●different●lock●control●mode:●Normally●Closed●Mode●and●

Normally●Open●Mode.

●

● Two●different●light●control●mode:●Delay●Mode●and●Trigger●

Mode,●and●light-on-by-calling●function●is●availible.

●

● Unlock●time●or●Light●delay●time●set●be●DIP●switches.

●

● Can●be●cascaded●up●to●3●units●to●control●up●to●6●Cameras.

1. Terminal Descriptions

2. Specifications

90mm

175 mm

60 mm

●

●

Power Consumtion:

0.25W●in●standby,●0.5●W●in●

actting

●

●

NC/NO, COM exchange contact:

250V●ac●7A

●

●

Monostable relay activation time:

●adjustable●

from●1●second●to●10●minutes●±5%

●

●

Working temperature:

●-5ºC●+45ºC

●

●

CCTV Power Output 1:

12V●500mA

●

●

CCTV Power Output 2:

12V●500mA

●

●

Input Frequency:

●47~63●Hz

●

●

Leakage Current

:●>2mA●/●240Vac