VEGA VEGAFLEX 54P (Profibus PA) User Manual
Page 45
VEGAFLEX 54P (Profibus PA)
45
Technical data
Connection cables
Two-wire sensor
- power supply and signal via one two-wire cable.
The line resistance depends on the supply voltage (see diagram).
Cross-section area of conductor
general 2.5 mm
2
Ground connection
max. 4 mm
2
Cable entry
2 x M20 x 1.5 (cable diameter 5 … 9 mm)
2 x
1
/
2
“ NPT with ExD housing
CE conformity
VEGAFLEX sensors meet the protective regulations of EMC (89/336/EWG) and NSR
(73/23/EWG). Conformity has been judged acc. to the following standards:
EMC
Emission
EN 50 081 - 1: 1992
Susceptibility
EN 50 082 - 2: 1995
NSR
EN 61 010 - 1: 1993
Display
Indication
scalable analogue and digital measured value
display (option).
An external measured value display powered by the sensor can be mounted up to 25 m
away from the sensor.
Signal output
Signal output
digital output signal in two-wire technology
(Profibus)
Two-wire technology:
The digital Profibus output signal (measuring signal) is modulated onto the power supply
and is further processed in the signal conditioning instrument or in the processing system.