.1 Technical data

General data

Series

19" module card, multipoint connector according to
DIN

41612, including transparent cover (lockable)

Weight

150 g (5.3 oz)

Power supply

Operating voltage

20 … 53 V AC, 50/60 Hz, 20 … 72 V DC

Max. power consumption

2 W, 3 VA

Fuse

-

Supply area

T

1 A, 253 V

-

Switching off possibility

min. 35 A at 253 V AC or 125 V DC

Sensor input (channel)

Quantity

2 x level detection or 2 x two-point control (min./
max.)

Response resistor

1 … 200 kΩ adjustable

Parallel resistor for fault monitoring

220 kΩ

Measuring circuit

max. 5 V eff., max. 1 mA

Permissible line capacitance

1 x 100 nF or 2 x 70 nF with min./max. control

Switching hysteresis

15 %

Relay outputs

Quantity

2

Mode

A/B switch (A - max. detection or overfill protection,
B - min. detection or dry run protection) adjustable
separately for each channel

Damping

500 ms

Contact

1 spdt for each output

Contact material

AgNi, hard gold-plated

Turn-on voltage

10 mV DC, ≤ 253 V AC/DC

Switching current

10 µA DC, ≤ 3 A AC, 1 A DC

Breaking capacity

750 VA, ≤ 54 W DC

Transistor outputs

Number, function

1 output, synchronously switching with the relay

Galvanic separation

Floating