Overfill protection acc. to WHG

Level detection with fault monitoring

Instrument

Oscillator

Level switch

Test certificate no.

VEGATOR

VEGASWING

SWING E82 Z

536 EX,

applied

81A EXD, 83A EXD

537 EX,

(Z)

636 EX

VEGASWING

SWING E82 C

compact instrument

applied

81A EXD and

SWING E82 R

83A EXD (C, R, T)

SWING E82 T

Level measuring instruments for the use in hazardous areas

Level detection with fault monitoring

Instrument

Oscillator

Type appr oval
certificate

VEGASWING

SWING E82 Z

applied

81A EXD, 83A EXD
(Z)

VEGASWING

SWING E82 C

applied

81A EXD and

SWING E82 R

83A EXD (C, R, T)

SWING E82 T

Product description

• The mounting of Ex-systems must be gen-

erally made by skilled staff.

• VEGASWING 81A EXD, 83A EXD with

enamelled tuning fork or plastic parts ac-
quiring static electricity (ECTFE-coated
tuning fork) have a warning label stating
measures which should be taken to avoid
dangers due to electrostatic discharges.
The contents of the warning label should
be noted.

• The explosion protection of the used elec-

trical equipment is only ensured when the
limit temperatures stated in the certificate
are not exceeded.

• In case of dangers due to oscillation and

vibrations, the appropriate parts of
VEGASWING 83A EXD should be secured
effectively against these dangers.

VEGATOR 425 (EX), 534 (EX) and 825 (EX) signal conditioning instruments can be also used.

Overfill protection

The information and conditions of the sup-
plied general type approvals must be noted
when a VEGASWING is used as part of an
overfill protection for vessels storing water
endangering liquids. The general type ap-
proval should be available at the installation
place.
VEGASWING should be only used in such
liquids, against the materials of the wetted
parts of VEGASWING are sufficiently chemi-
cally resistant.

DruckbehV

In a test acc. to TRB 801 no. 45 VEGASWING
was tested on the suitability for the use in
pressurized vessels (DruckbehV). The pres-
sure and temperature information to certified
instruments are stated under "1.3 T echnical
data“.