VEGA VEGASON 71 - 1 … 75 - 1 User Manual
Page 11
Technical Information
71 - 1 … 75 - 1
11
Installation examples for solids
-
Select sensor type and installation in relation to
max. level to be measured.
-
Protect the inner side of the socket piece from
corrosion or use non-corrosive material.
-
Always direct the sensor (sound pulse) to the
centre of the silo.
-
Install sensor as far as possible from the filling
entry.
-
When using round ceilings, mount the sensor
half way between silo middle and edge.
Installation with cylindrical
socket piece
Installation with flanged
gimbal
Installation in open silos via
bracketry
socket piece length L at:
(dimensions in mm)
VEGASON
73 - 1
74 - 1
75 - 1
at socket
100
400
–––
–––
piece ø
150
400
300
300
200
500
400
400
250
600
500
500
300
–––
600
600
350
–––
700
700
Min. distance
800 …
800 …
1000 …
1000
1100
1200
Installation errors
(at tanks or silos)
L
45
°
ø
The socket piece
should not be
covered by the
product.
The socket piece
should not have
weldment joints.
Access too small.
Socket pieces in
the centre of
round tank ceilings
are not recom-
mended for the
sensor installation.
The beam should
not cross the
material inflow.