5 technical data – VEGA VEGAFLEX 52K User Manual
Page 8
Advertising

8
VEGAFLEX 52K
The min. supply voltage depends on the sensor current.
0
4
22
mA
14
15
36
V
Range of the required
terminal voltage on the
sensor
Sensor current
Product description
1.5 Technical data
Power supply
Supply voltage
- two-wire sensor
24 V DC (15 … 36 V DC)
- four-wire sensor
24 V DC (20 … 72 V)
230 V AC (20 … 250 V), 50/60 Hz
fuse 0.315 A TR
Current consumption
- two-wire sensor
max. 22.5 mA
- four-wire sensor
max. 60 mA
Power consumption
- two-wire sensor
max. 810 mW
- four-wire sensor
max. 1.2 W
V
9
1000
680
500
250
0
20
22
24
26
28
30
32
34
36
15 16
18
Voltage limit
non Ex sensor
Voltage limit
Ex sensor
HART
®
load
Voltage supply
Measuring range
VEGAFLEX 52
0.3 ... 20 m
Output signal
4 … 20 mA current signal, load max. 500
W