1.2 Technical data and dimensions
General
Series
instrument for front panel mounting
Dimensions
W = 96 mm, H = 48 mm, D = 110 mm
Weight
appr. 200 g
Housing material
plastic PPh
Terminals
max. 1,5 mm
2
Ambient conditions
Permissible ambient temperature
-10
°C … +60°C
Storage and transport temperature
-20
°C … +80°C
Power supply
Voltage supply
20 … 250 V AC, 20 … 72 V DC
Power consumption
1 … 9 VA, 1,5 W
Electrical protective measures
Protection class
II
Overvoltage category
II
Protection
- front
IP 40
- housing
IP 20
Inputs
Transmission
digital
Connection line to the signal condit. instrument
2-wire (screened cable recommended)
Line length
max. 1000 m
Digital indication
LCD-display
5-digit with minus sign
Height of figures
12,7 mm
Decimal point
individually selectable
88888
hl
VEGADIS 174
112
96
48
104,5
5
1,5
90
42,5