Version with plastic housing, Electrical connection – VEGA VEGAPULS 45 4 … 20 mA; HART compact sensor User Manual
Page 30

30
VEGAPULS 42, 44 and 45 – 4 … 20 mA
Electrical connection
+
-
+
-
2.23274
1
(+) L1
2
Communication
8
7
6
5
Display
4-20mA
4-
+3
N
-
OK
+
ESC
Tank 1
m (d)
12.345
+
-
Display
5
6
7
8
Communication
2 -
+
4-20mA
1
2.23272
-
OK
+
ESC
Tank 1
m (d)
12.345
Power supply
4 … 20 mA (passive)
1)
To the indicating instrument in the
sensor lid or to the external indicating
instrument VEGADIS 50
Sockets for connection of
the HART
®
handheld or
the VEGACONNECT
Two-wire technology in
plastic housing
(loop powered)
Four-wire technology in
plastic housing
(separate supply)
Power supply
4 … 20 mA (active)
2)
Terminals
(max. 2.5 mm
2
wire cross-section)
Opening
tabs
Pluggable
adjustment
module
MINICOM
1)
4 … 20 mA passive means that the sensor
consumes a level-dependent current of
4 … 20 mA (consumer).
2)
4 … 20 mA active means that the sensor provides
a level-dependent current of 4 … 20 mA (current
source).
Version with plastic housing
Cable entry
M20 x 1.5
To the display in the lid or
the external indicating
instrument