4 Adjustment with PACTware

RS232/Ethernet connection • VEGAMET 391/624/625, VEGASCAN 693, PLICSRADIO C62

30325-EN-130701

1. In the device catalogue, first select the "VEGA USB" DTM from

the category "Driver" and transfer it, e.g. by double clicking, to the

project window.

2. Select the VEGAMET 391 DTM from the category "Gateways"

and transfer it into the project window.

3. Select the requested sensor DTM from the category "Device" and

transfer it to the project window.

4. Now open the DTM by double clicking on the sensor in the project

window and carry out the desired settings, see chapter "Param-

eter adjustment".

Fig. 2: Project with VEGAPULS

Project creation, VEGAMET 624 with sensor

The following example shows a typical project containing a sensor

connected to a VEGAMET 624. Communication with VEGAMET

624 is carried out in this example via network and Ethernet. We

recommend using the "VEGA project assistant" as this considerably

facilitates project creation and helps avoid errors. All participating

components are found automatically and integrated into the project.
In case the planning is nevertheless carried out manually, e.g. when

creating an offline project, the following DTMs must be added to the

project tree:
1. In the device catalogue, first select the "VEGA Ethernet" DTM

from the category "Driver" and transfer it, e.g. by double clicking,

to the project window.

2. Select the VEGAMET 624 DTM from the category "Gateways"

and transfer it to the project window.

3. Select the requested sensor DTM from the category "Device" and

transfer it to the project window.

4. Select the "VEGA-Ethernet" DTM in the project tree and select via

the right mouse key the menu item "Additional functions - Change

DTM addresses". Enter in the field "New address" the IP address

or the Host name the VEGAMET should get later on in real opera-

tion.

Connection, VEGAMET

624 via Ethernet