VEGA VEGAPULS 62 (≥ 2.0.0 - ≤ 3.8) Profibus PA User Manual
Page 13
1
3
2
100%
0%
4
Fig. 3: Measuring range (operating range), max. measuring distance and
reference plane
1
full
2
empty (max. measuring distance)
3
Measuring range
4
Reference plane
Information:
If the medium reaches the antenna, buildup can form on it and cause
faulty measurements later on.
The emitted radar pulses of VEGAPULS 62 are electromagnetic
waves. The polarisation plane is the direction of the electrical wave
component. Its position is marked on the instrument.
1
Fig. 4: Position of the polarisation plane with VEGAPULS 62
1
Marking hole
Make sure that all parts of the instrument in contact with the measured
product, especially the sensor element, process seal and process
fitting, are suitable for the existing process conditions such as process
pressure, process temperature as well as the chemical properties of
the medium.
Polarisation plane
Suitability for process
conditions
VEGAPULS
62 • Profibus PA
13
4 Mounting
28445
-EN
-090305